CIE Division 8 - TC8-03: Survey of Gamut Mapping Papers


Morovic & Luo (1998c)

The UniGMA, LCUSPH, CARISMA, GCUSP and LLIN methods previously described by the authors are implemented in CIECAM97s and investigated by making reproductions of CRT images on two printed media, which are then evaluated in terms of accuracy. The results have shown the influence of media difference, which is also a difference in gamut size, on the performance of GMAs. The gamut difference between the two reproduction media, which was seven per cent in terms lightness range, resulted in a 60 per cent change of accuracy score range. This indicates the importance of gamut difference for the performance of various algorithms and could be the reason for some of the differences between previous studies. The evaluation of reproductions made with the various GMAs suggested that the CARISMA and GCUSP algorithms again performed best, whereby the GCUSP algorithm had a significantly smaller variance of accuracy in terms of its scores for individual colour regions in the test images used.
 


Last updated: 17 August 1999 by Jan Morovic